Fm200 system maintenance tips may 20, 2015 vesdahssdsystems leave a comment if you are looking for a fire suppression system that you can use in many areas that require special treatment such as an area where computers will be, robotic equipment, or the storage of media, the fm200 system is what you need in order to keep everything safe. Hazard identification response none storage keep container tightly closed. We can provide the inspection and maintenance schedule to keep your system in compliance, as well as keep accurate inspection and maintenance records that are required by. Ecaro 25 fire suppression system orr protection systems. Fike fm200 clean agent fire suppression system with the shp pro control panel fm200 system w shp pro specification page 2 of 8 pn. We install and service kidde fm200 fire suppression systems. For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. Preventative maintenance checks and services pmcs for fm200 and water washdown system wws up tm55190524324p fm200 firefighting system for landing craft utility lcu2000 class manual. Our clean agent fire protection system, using dupont fm200 as thefm200 fe227ea heptafluoropropane cf3chfch3extinguishing agent, leaves no residue and doesnt require. Fikes ecaro25 clean agent fire protection system requires 20% less clean agent per cubic footmeter than hfc227ea or fm200 clean agent fire suppression systems and an incredible 38% less clean agent than fk5112 thats a significant cost savings. The fm 200 clean agent system materials and equipment shall be standard products of the suppliers latest design and suitable to perform the functions intended.
Introduction fike is pleased to provide a design, installation and maintenance manual for our clean agent fire suppression systems w fm200 agent. Manuals 06106 armiii 101832 control and installation manual 06128 countdown timer install instructions 06152 manual actuator manual 06344. Automatic and manual activation can be accomplished with the same valve. Specification for a fm 200 national fire alarm code. Disposal none other hazards direct contact with the cold gas or liquid can cause freezing of exposed tissues. Product overview fm200 fire suppression system clean agent power protects people and property n nonconductive and will not shortout electronic equipment or thermally shock detects fire in early stages n suppresses class a, b and c fires n less visual obscuration and minimal risk to personnel n colorless, odorless clean agent leaves no residue n electrically nonconductive. Tiein of fm 200 panel to house fire alarm andor security system. Acoma drive, suite 106 scottsdale, az 85260 usa telephone.
Fm200 fire extinguishing agent with expellant revision date. Design, installation, and maintenance manual for engineered hfc227ea systems. The clean agent fire extinguishing system shall consist of fm 200, agent cylinders, 1800. Handle in accordance with good industrial hygiene and safety. Impulse technology efficient and cost effective as with previous fike systems, the impulse valve technology continues to allow for a flexible, modular des. Fike design, installation and maintenance manual pn 06215. Page 2 fikes policy is one of continual improvement and the right to change a specification at any time without notice is reserved. Fm200 is not a direct replacement for existing halon 1 installations due to the difference in agent quantity and discharge characteristics the minimum fm200 design concentration for class a hazards is 6 4% for ul listed systems or 7 17% for fm approved systems, and for class b hazard is at least 9 0%. Confires provides complete fm 200 system services, including sales, installation, inspection, recharge, testing, and more.
The fike impulse valve technology can be field tested and reset, thereby eliminating flash bulb testing. This is a single volume technical manual arra nged in 6 sections, followed by an appendix. If you are searched for a ebook fike fire alarm manual cheetah trouble codes in pdf form, then you have come on to the loyal site. About this manual this manual is a comprehensive guide that contains all the information necessary to design, install and maintain the fm200 engineered extinguishing system. Fike is pleased to provide a design, installation and maintenance manual for our clean agent fire suppression systems w fm200 agent. The abort station employs a momentary mushroom pushbutton switch which, when pressed, opens the actuator circuit by interrupting electric current.
Pdf fike fire alarm manual cheetah trouble codes read. Next preventative maintenance checks and services pmcs for tunnel fm200 system. Dupont fm200 also known as hfc227ea is a clean agent fire suppressant and is probably the most popular of the clean agent family meeting the nfpa standard 2001 clean agent fire extinguishing systems. Maintenance manual, pn 06202 or 06215 and the fike flow calculation computer program. The clean agent fire extinguishing system shall consist of fm200, agent cylinders, 1800. Shppro is the reliable, conventional fire suppression system for smaller applications. The fm200 agent is stored in cylinders as a liquid and pressurized with nitrogen, which makes for a highly compact fire suppression system. D the manual release switch shall be a fike pn 101638 or a manual pull. Learn how the the fm200 clean agent fire protection system hfc227ea leaves. Refer to fike hfc227ea fm 200 instruction manual for liquid level indicator lli, pn 06107. Safety data sheet fm200 fire extinguishing agent with. This document has been revised to incorporate the latest design requirements found in nfpa standard 2001, as well as the most uptodate information available for our products. The gate must not exceed 12 feet in length and weigh more than 300 pounds please see technical specifications on page x. The mighty mule gate opener is designed for installation on a pulltoopen single leaf gate gates that open into the property.
Maintenance manual for the clean agent fire extinguishing system employing fm 200 shall be submitted after complete installation. Fm 200 discharges gas 1,1,1,2,3,3,3heptafluoropropane directly onto the surface of combustible materials. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Refer to fike hfc227ea fm200 instruction manual for liquid level indicator lli, pn 06107. Exposure controlspersonal protection engineering control measures use with adequate ventilation. Fm200 fire suppression system extinguishes fires mainly by physically cooling the flame. In light of the covid19 pandemic, fike corporation is taking the following measures to protect our employees and business partners from the virus, limit the spread of the virus in our global communities, and continue to support your business with essential lifesafety products and services. Operation a magnet equipped float moves with the liquid level along the unit stem. Fm200 fire suppression system hepdro fire protection. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. Unmatched in the industry for sheer versatility and ease of installation, this singlehazard control system boasts incredible power and can be easily configured for use within a wide range of industries and fire suppression applications. Design, installation maintenance manualfm200fike gases. Shppro fire detection and fire protection system fike. Maintenance manual for the clean agent fire extinguishing system employing fm200 shall be submitted after complete installation.
Interlock conduit and wiring to ventilation equipment, dampers, and shunttrip breakers 3. Whilst every care has been taken to ensure that the contents of this document are correct at time of publication, fike shall be under no liability whatsoever in respect of such contents. The system shall provide a fm200 minimum design concentration of 6. Conventional fire alarm and suppression system fike. Fm200 fire suppressant hfc227ea can be safely used where. Fm 200 suppresses fire fast using a combination of chemical and physical mechanisms. Level readout is obtained by simply removing the protective cap and pulling out a calibrated tape until magnetic interlock with the float. January, 2008 3 the installing contractor must have a minimum of five 5 years experience in the design, installation and testing of clean agent, or similar, fire suppression systems. Fm200 is rated for use on class a, b, and c type fires. Specification for a fm200 national fire alarm code. Sv series, mv series, lv series issued february 1, 2009. In addition, the superior physical properties of dupont fe25, the clean agent used. The system and components shall be a kidde fire suppression system as. About this manual this manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system.
May 20, 2015 fm200 system maintenance tips may 20, 2015 vesdahssdsystems leave a comment if you are looking for a fire suppression system that you can use in many areas that require special treatment such as an area where computers will be, robotic equipment, or the storage of media, the fm200 system is what you need in order to keep everything safe. Tiein of fm200 panel to house fire alarm andor security system. This technical manual provides the necessary information for the design, installation, operation and maintenance of a chemetron fm200 sigma series engineered system. Design installation maintenance manual fm200 fike fm200 cleanagent fire suppression system with pyrochem the design, equipment, installation, manual pull stations, all aspects of system operation and. And it discharges in 10 seconds or less, extinguishing a fire. Fm 200 clean agent fire suppression system fast, effective clean agent fire protection. Push button agent abort switch cut sheet gemcom inc. The design, equipment, installation, testing and maintenance of the clean agent suppression system. Do not call the fike safety technology support department unless your distributor has first given their advice and attempted to rectify the issue. Fm 200 is a clean agent fire suppression system designed specifically to protect sensitive electronic equipment. Now, fike expands its clean agent offering with the addition of. Fikes proinert2 is the safest, most economical natural fire protection solution.
The primary extinguishing mechanism of fm200 is heat absorption, with a secondary chemical contribution from the thermal decomposition of fm200 in the flame. There should be local procedures for the selection, training, inspection and maintenance of this equipment. Push button agent abort switch the push button agent abort switch provides a temporary manual means for interrupting the agent actuation circuit between the initial alarm and automatic release. Dupont fm200 fire suppression systems american fire. Fm200 fire suppression dc, md, va installation, inspection. Fikes newly released suppression cylinder valve improves system performance and maintenance. Fm200 hfc227ea is formed from the elements carbon, fluorine and hydrogen cf3chfcf3heptafluoropropane. Carbon dioxide co2 clean agent fire suppression system.